<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-11 22-44-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.10 MHz 5/5, 58 dBuV RMC
Pilot RDS Phase Difference
4.1 kHz 4.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 74 kHz 9961 0,1104
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
4,4 dBr 6,48 dBr 7,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 1 22:44, 11.08.2025
RT
-
AF EON
87.6, 87.7, 90.2, 90.4, 90.6, 92.3, 95.3, 96.4, 97.3, 99.1, 100.7, 101.2, 101.6, 102.6, 103.1, 103.2, 103.3, 103.6, 104.1, 104.8, 106.7, 107.2, 107.3, 107.5, 107.9 MHz -
FM Scope Station: 103.10 MHz, signal: 4/5 (58 dBuV) Max at: 74 kHz MIN: 3 kHz % above 75 kHz: 0,1104 Acquired: 2025/08/11 22:43:17 Total samples: 9961 Equivalent time: 0:08:18 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 7,9 dBr MIN: 4,4 dBr AVE: 6,48 dBr % above 10,2 dBr: 0,0 Last value: 7,4 dBr (2025/08/11 22:43:17) Station: 103.10 MHz, signal: 4/5 (58 dBuV) 22:36 22:37 22:38 22:39 22:40 22:41 22:42 22:43 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality